Project Examples
Retained by a Council to use expertise in dealing with low frequency noise and ground borne vibration due to a textile factory:
NVM proposed a scope of work that involved surveys in the affected residential property and then tests with noise measurement investigations at the factory to ascertain the paths for the nuisance. With reference to BS4142, the complaints were justified. Best practicable means were deemed to be available.

Requested by a North-West City Council to monitor vibration due to construction site compaction:
A large retail development on made-up ground where large-scale consolidation was needed, NVM provided specialist noise measurement and vibration monitoring within a permanent showman's mobile home encampment and advice to the Council regarding scale of vibration and amelioration.

Shell Refinery, UK
Investigation using the acoustic intensity localization technique to determine the contributions made by a building, ducting and silencers to a large compressor installation causing a low frequency environmental noise (25Hz) radiation problem.

Intel, Ireland
Microelectronic and photolithography tool vibration tests on floors and pedestals.
Seagate, Northern Ireland
Wafer Fab Floor noise measurement and vibration issues, tool vibration criteria.

Nuffield Hospitals, North of England
Noise measurement and vibration issues, environmental, structural. Floor response factor attainment relating to operating theatres and ward bedrooms.

Lightwater Valley Leisure park, Yorkshire
Assessed large scale music venue impact on local village.

Alton Towers Leisure Park- Hotel Development, Midlands
Noise study and general advice. Sound insulation tests.

A1/M1 Link Motorway Noise, Yorkshire
Noise measurement surveys relating to roadway surfaces and complaints from residents.

Gas Compressors, Romania
High frequency vibration fatigue failures were occurring. Noise measurement investigations and tests performed onsite. Compression/Acoustic forces were diagnosed. Finite element analysis employed in attempts to reduce the vibration levels.

Rolls Royce, Gas Turbine Gearbox, UK
Vibration mode tests on gearbox rotors.

Offshore UK - Reciprocating Gas Compressors
Noise measurement and Vibration assessment and diagnosis relating to three-point skid mounted machinery.

Offshore Middle East Machinery vibration troubleshooting
Fire pumps, GRP gas cooling piping vibration problems- surveys, tests, recommendations for reducing vibration.
 Tel: (+44) 01924 849721 | Email: contact@nvm-consultants.co.uk